Blog

Polycarbonate Daylighting Systems for a New Warehouse: What Does Each Option Gain, and What Does It Give Up?

At a glance

  • For a new warehouse, the realistic daylighting options are roof daylight strips, double-glazed insulated roofing, vaulted rooflights, and translucent wall bands.
  • Each option trades daylight against insulation and solar heat gain, so light transmission, U-value and solar heat gain coefficient should be read together.
  • Danpal builds engineered system panels joined by a standing seam and connectors, not loose sheets, for high air and water tightness.
  • According to Danpal, in 95% of cases it delivers systems manufactured to size, eliminating off-cuts on site.

Danpal

Published:

A new warehouse that wants to maximize natural light usually weighs three translucent roof options: single-glazed daylight strips or a full translucent roof built from Danpalon panels, a double-glazed roofing system such as Danpatherm RK7, and a project-specific build-up using a Danpal proprietary product such as Controlite Roof. Translucent means light-transmitting but not see-through: these systems admit daylight without giving a view out. Each option gains daylight and gives something back, either solar heat control or thermal insulation, because the same panel properties govern all three. This article sets out those trade-offs as of 2026. Where a view through the wall is needed, Danpal recommends glass. Where the need is the passage of natural light, its solutions are in most cases the better choice, and a well-designed building can use both.

What daylighting options does a new warehouse realistically weigh?

The daylighting options for a new warehouse differ mainly in how many polycarbonate skins they use and how they are jointed. Each of them is a system panel: Danpalon panels with a standing seam at the edge, joined panel to panel with a connector and dedicated system components. The result is an engineered system rather than a set of sheets, designed for high air and water tightness and to carry wind and snow loads. Danpal pioneered the standing seam, and the system-panel approach became the industry standard.

  • Single-glazed Danpalon panels, run as daylight strips or as a full translucent roof. Multicell panels are built from multiple internal walls rather than solid material.
  • Danpatherm RK7, Danpal's double-glazed roofing system, with two skins and optional translucent insulation in one assembly.
  • Controlite Roof, one of Danpal's own proprietary products, tailored to the project like every Danpal solution.

Where the daylight strips sit in a main roof from another supplier, the connection between the two is part of the decision. Danpal provides technical support and drawings from the specification phase and can accompany the installation on site.

What does each option gain, and what does it give up?

Every option trades daylight against heat and insulation, because thickness, color and insulation change light transmission, solar heat gain and thermal transmittance together. Light transmission is the share of incident daylight a panel passes into the building. The solar heat gain coefficient (SHGC) measures how much solar energy comes in with that light. U-value is thermal transmittance in W/m²·K, and lower means better insulation.

Option What it gains What it gives up
Clear, thinner Danpalon panels The most daylight in the range The most solar heat gain
Reflective Grey Danpalon panels The least solar heat gain Most of the daylight
Thicker multicell Danpalon panels Lower panel Ug Some light transmission
Danpatherm RK7 with insulation A lower U-value than uninsulated RK7 Roughly half the light transmission of uninsulated RK7

Tested in accordance with ASHRAE 74-1988 procedures, clear Danpalon transmits 86% of visible light as a 4 mm compact panel. According to Danpal's technical data, this falls to 41% at 50 mm, while the SHGC falls from 0.81 to 0.43 over the same range. Reflective Grey transmits between 10% and 20% of visible light, with an SHGC between 0.21 and 0.29. These figures are indicative per color and thickness band and may change within manufacturers' production tolerances.

The pattern suggests that the daylight decision for a warehouse is a balance to set against the building's heating and cooling needs, not a single figure to maximize.

What do thicker panels and insulated roofing give up in daylight?

Lower thermal transmittance costs light transmission at every step. For the multicell Danpalon panel alone, Danpal gives CSTB calculated Ug values of 2.4 W/m²·K at 12 mm, 1.9 at 16 mm and 1.5 at 22 mm. According to Danpal's technical data, the 35 mm panel has a Ug of 1.2 W/m²·K and the 50 mm panel 0.85 W/m²·K. Ug describes the panel without connectors or other system components, so it is not the U-value of the roof.

For the Danpatherm RK7 double-glazed roofing system, Danpal publishes:

  • a U-value of 1.18 W/m²K without insulation and 0.79 W/m²K with insulation;
  • light transmission of up to 35% and up to 19% respectively;
  • an SHGC of 0.4 and 0.3 respectively;
  • a Broof (t1) classification for external fire exposure of roofs under EN 13501-5.

Each U-value should be confirmed for the chosen configuration. Fire classification should also be checked for the specific panel, system configuration and market. Danpal offers a thermal simulator as part of its project support, for the thermal side of the decision.

What does a translucent polycarbonate roof gain and give up compared with glass?

Danpal states that, compared with glass, polycarbonate has advantages in weight, installation complexity, safety and thermal insulation. What it gives up is the view through: polycarbonate suits a warehouse roof where the need is natural light rather than a view. Lighter glazing also means less load on the supporting structure.

Frequently Asked Questions

Which option admits the most daylight?

Clear, thinner Danpalon panels admit the most daylight, and they also admit the most solar heat. Thicker panels, Reflective Grey and insulated double glazing each give up light in return for heat control or insulation.

Does adding insulation always reduce daylight?

Yes. Insulation in a double-glazed roofing system lowers both its U-value and its light transmission: Danpatherm RK7 goes from up to 35% light transmission uninsulated to up to 19% insulated.

How does a translucent roof perform against hail?

Tested to ASTM E-822-81, a Danpalon panel repels hailstones of 25 mm traveling at 21 m/sec with no penetration.

Can individual panels be replaced later?

Depending on the system, individual Danpalon panels and accessible components can be replaced without replacing the complete installation. In double-glazed systems, one side can be removed and replaced while the other remains in place.


About this article

Danpal publishes this article under its own name and is responsible for its accuracy. Articles are researched and drafted with AI assistance and approved by Danpal before publication; publication and update dates reflect substantive edits, not automated refreshes. Last updated: 2026-11-17

Ready to get started?

See how Danpal can help.