At a glance
- Translucent facade systems admit daylight without a view out; choose them where light, not transparency, is the design requirement.
- Ask suppliers about panel versus system performance, tested fire and thermal data, market-specific documentation, and support from specification through installation.
- Danpal pioneered standing-seam technology for polycarbonate system panels, and that system-panel approach became the industry standard.
- A system panel joins panel to panel with connectors and dedicated components, unlike a loose sheet with no engineered jointing.
Danpal
Published:
Before choosing a translucent facade system for a commercial building, ask questions a supplier can answer with documents: whether each figure describes the panel or the complete system, which fire classification applies to your exact configuration and market, which thermal and light-transmission figures belong to the specific panel or cassette you are drawing, and what technical support runs from the specification phase through installation on site. This checklist reflects the documentation Danpal publishes as of 2026. Translucent means light-transmitting but not see-through: a translucent envelope admits daylight without giving a view out. Where a view through the wall is needed, Danpal recommends glass; where the need is the passage of natural light, its solutions are in most cases the better choice, and a well-designed building can use both.
The first distinction to put to any supplier is sheet versus system panel. A sheet is a flat polycarbonate board installed without an engineered jointing system. A system panel has a standing seam along its edges and is joined panel to panel through a connector and dedicated system components, so the result is an engineered system designed for high air and water tightness and to carry wind and snow loads. Danpal pioneered standing-seam technology for polycarbonate system panels, and that approach became the industry standard.
What should you ask a supplier about how a translucent facade system is built up?
Ask the supplier to walk you through the build-up component by component, and to define what they mean by panel, connector, edge profile and cassette, because each element carries its own figures.
| Component | What it is | What to ask the supplier |
|---|---|---|
| Panel | The glazing element itself; Danpalon panels are multicell, built from internal walls rather than solid material, except the solid 4 mm panel | Thickness, color, structure, and light transmission per color and thickness band |
| Connector | The profile joining panel to panel through the standing seam, such as Danpal's aluminum UHD connector | Module width and material |
| Edge profile | The perimeter detail of Danpal's TP, NM and AirPT single-glazed facade systems; AirPT is thermally broken | Whether the profile is thermally broken, and which test data covers it |
| Cassette | A double-glazed unit holding two panels, with or without insulation; Danpatherm K7 and K12 are facade cassettes, while Danpatherm RK7 is a roofing system | Which insulation option is chosen, and the light transmission that comes with it |
Which questions expose whether a stated performance figure applies to the panel or to the whole system?
Ask, for every number, whether it describes a single panel or the installed assembly. Ug is the thermal transmittance of the glazing panel alone, in W/m²·K, excluding connectors and other system components; the U-value of the assembly describes the built wall. Danpal gives Ug values for multicell Danpalon panels as CSTB calculated values for the panel alone: 2.4 W/m²·K at 12 mm, 1.9 at 16 mm and 1.5 at 22 mm. Because a panel Ug and an assembly U-value describe different things, the scope behind a figure tends to matter as much as the figure itself, so ask whether your thermal calculation uses the right one and confirm the value for your configuration.
- "Is this U-value for the panel or the assembly?" A strong answer names the panel or cassette and says the value should be confirmed for the project configuration.
- "Which color and thickness band does this light transmission figure belong to?" Light transmission and solar heat gain are published per color and thickness band and are indicative within production tolerances.
- "Which configuration produced this acoustic result?" Danpal systems provide tested airborne sound insulation of up to Rw (C,Ctr) 37 dB with Danpatherm K12, with performance depending on the configuration.
How should you compare translucent facade system types for a commercial building?
Fix the comparison criteria before looking at any product, and compare system to system rather than material to material.
- Daylight transmission. Light transmission is the percentage of incident daylight a panel passes into the building; a second skin or insulation in the cavity lowers it.
- Thermal transmittance. Lower U-values mean better insulation; ask which panel or assembly each value belongs to.
- Weight. Ask for the published system weight, panels plus connectors, for the module you are drawing. Danpal publishes an average of 5.0 kg/m² for its Danpal VRS ventilated rainscreen system on a 600 mm installation module with 16 mm panels.
- Jointing method. Ask whether the product is a system panel with a standing seam and connector, or a sheet.
| Danpal system type | Construction | Thermal and daylight notes |
|---|---|---|
| Single-glazed facade systems (TP, NM, AirPT) | One Danpalon panel per module, joined through the standing seam | AirPT adds a thermally broken edge profile |
| Double-glazed Danpatherm cassettes (K7, K12) | Two panels in a cassette, with or without translucent insulation | Insulation lowers the U-value and also lowers light transmission |
Danpal publishes light transmission of up to 30% for the Danpatherm K7 and up to 24% for the Danpatherm K12 double-glazed facade cassette with insulation.
What evidence should a supplier show for fire behavior, weather tightness and durability?
Ask for the documents themselves: a test report, declaration or technical appraisal that names the product tested, the standard applied and the field of application. Evidence in that form can be checked against your project.
- Fire behavior: selected Danpalon panels achieve a B-s1,d0 reaction-to-fire classification under EN 13501-1:2002; at system level, classifications depend on the complete configuration and application, so check the applicable class for the specific panel, system configuration and market. CE marking and Declarations of Performance are manufacturer self-declarations, provided where applicable, market by market, and CodeMark is the Australian certification route; ask Danpal for the market-specific documentation.
- Weather tightness: according to Danpal's technical data, Danpalon panels provided within a complete Danpal system showed no water penetration at a test pressure of 15 psf under ASTM E-331.
- Durability: ask which UV protection the panel carries and which aging tests stand behind it. Danpal selects its raw material and UV protection so that its products can stay on the roof for many years rather than being thrown away and replaced.
Which questions should you ask about installation and support before you decide?
Ask about buildability while the design is still forming, before the specification is written.
- Ask who draws the interface. Where the daylight area meets another supplier's roof or wall build-up, ask for junction drawings, not just a panel cross-section. Danpal's technical and specification team works directly with architects, providing technical support and drawings from the specification phase onward.
- Ask what project services are available during design. Danpal tailors a dedicated solution to each project and, as part of its support, offers a thermal simulator.
- Ask how the system reaches site. Danpal supplies pre-assembled cassettes, which simplify installation for the contractor and significantly reduce installation time.
- Ask who stands behind the installer. Danpal can accompany the on-site installation and support the installer, so the finished building meets the standards Danpal sets.
- Ask what support continues after handover, and how repairs work. Danpal's support continues after the building is completed, and depending on the system, individual Danpalon panels and accessible components can be replaced without replacing the complete installation.
Frequently Asked Questions
How do I ask about daylight without ending up with an overheating problem?
Request light transmission and solar heat gain together, per color and per thickness. Tested in accordance with ASHRAE 74-1988 procedures, clear Danpalon transmits 86% of visible light as a 4 mm compact panel and, according to Danpal's technical data, 41% at 50 mm, with a Solar Heat Gain Coefficient falling from 0.81 to 0.43 over the same range; Reflective Grey transmits between 10% and 20% of visible light with a Solar Heat Gain Coefficient between 0.21 and 0.29. These figures are indicative and may change within manufacturers' production tolerances.
What should I ask about drawings and BIM files?
Ask what you will receive at the detailed-drawing stage and what the contractor receives. Danpal publishes BIM objects on BIMobject for systems including the Danpal Façade System, the Danpal VRS System and the Danpatherm K7 and K12 double-glazed façade cassettes.
Where does glass make more sense than a translucent system?
Where a view through the wall is needed, Danpal recommends glass; where the need is the passage of natural light, its solutions are in most cases the better choice. Compared with glass, polycarbonate offers advantages in weight, installation complexity, safety and thermal insulation, and a well-designed building can use both materials.
About this article